Intensive Care Coverage Without Limits
KT 1000
A transport incubator is more than just a simple transport device; it is a mobile life support system that maintains the newborn’s stability in challenging external environmental conditions. The transfer process involves factors that cause significant heat loss and stress for the newborn, such as fluctuating ambient temperatures, increased airflow, vibration, and limited opportunities for intervention.
The KT 1000 is equipped with advanced engineering solutions to manage these challenging variables and maintain clinical standards during transfer.
- Thermal Stability Independent of External Conditions
- Uninterrupted Power and Mobility
- Advanced Battery Technology
Product Features
Quick Start and Superior Heat Retention
In transportation processes where every second counts, speed is of the utmost importance. The KT 1000 fully addresses this need with its advanced heating algorithm:
Critical Heating Time: Rapid heating performance that reaches the target temperature in less than 30 minutes minimizes wait times during emergency transfers.
Double-Wall Protection: The special double-wall canopy design not only blocks airflow from the outside environment but also maximizes energy efficiency and thermal stability by retaining the heat generated by the device for an extended period.
Uninterrupted Response and Ergonomics Under All Conditions
The KT 1000 is designed to eliminate physical constraints in ambulances and transport vehicles:
Adaptive Canopy Design: Depending on the ambulance’s layout and the location of medical personnel, the direction in which the canopy opens can be easily adjusted by the user. This flexibility—in addition to the front and rear hatches—enables uninterrupted and rapid access to the infant from any angle, even in confined spaces.
Integrated Treatment Modules: The device is not merely a heater; it is a comprehensive platform that can integrate an aspiration unit and auxiliary medical equipment (ventilator, monitor, etc.). This ensures that all support units required during transport operate in ergonomic harmony.
Thermal Stability Independent of External Conditions
Energy management, the most critical aspect of transfer safety, is at the highest level in the KT 1000:
Advanced Battery Technology: The advanced battery system, which offers up to 4 to 6 hours of use and fast-charging capabilities, ensures uninterrupted temperature stabilization throughout the transfer without relying on an external power source.
Precision Microclimate: The interior cabin design, which is unaffected by changes in the external environment, minimizes the baby’s metabolic load, thereby reducing transfer stress to a minimum.
KT 1000: Flexible and Powerful Integration Solutions
The NOVOS KT 1000 Transport Incubator is not just a transport unit; it is a modular system that provides a fully equipped intensive care environment for newborns, even during the most critical transfers. With its optional solutions designed to adapt to different transfer scenarios and medical needs, it streamlines these processes.
Optional Stretcher Options Suitable for Any Situation
The KT 1000 meets all your mobility needs, from ground ambulances to air ambulances and in-hospital transfers.
Stretchers with Advanced Securing Mechanisms: These stretchers offer flexible usage with four different ambulance-compatible options that can be easily locked into the vehicle to maximize transfer safety and minimize vibration.
Height-Adjustable (Hydraulic/Mechanical) Stretchers: There are height-adjustable stretcher options available that protect the ergonomics of healthcare personnel during in-hospital transfers and offer easy maneuverability.
Universal Connectors for Various Models of Ventilators and Infusion Pumps
Ensuring uninterrupted respiratory support during newborn transport is of vital importance. The KT 1000 features universal integration capabilities, allowing healthcare facilities to make the most efficient use of their existing equipment.
Wide Brand and Model Compatibility: Offers connection adapters and transport rails specifically designed for transport ventilators and infusion pumps of various models and brands commonly used in the industry.
Secure Mounting: Ensures that the ventilator locks securely and safely to the incubator’s body even during ambulance rides with severe shaking, preventing the risk of it falling or coming loose.
Modular Configuration: Provides healthcare personnel with the flexibility to easily remove, install, or reposition the ventilator in emergency situations.
Integrated Vacuum Unit Designed Specifically for Infants
Gentle and Safe Pressure Management: Enables safe and controlled suctioning within ultra-gentle, low-pressure ranges that will not damage the delicate tissues of newborns.
Uninterrupted Protection in Critical Moments: Fully integrated into the device, this unit operates without being affected by power outages or external power source failures that may occur during transport, ensuring the baby’s airway remains open at all times.
In Plain Sight and Within Reach: Thanks to its design integrated into the incubator’s body, it allows clinicians to intervene within seconds in emergency situations.